Error Number: 15162


Error Message:

ALE: timeout moving bay <bay#> shutter cylinder


Applies to:

  • Platesetter_3244

Service Information:

Check for mechanical interferance, Check alignment of shutter cylinder Hall effect sensors, and cabling.


Operator Action:

Resume, Open side panels and check that shutter is not obstructed. Call Creo service if problem persists.


Cause:

  • Bay shutter closed sensor was not detected within "shutter_delay" while closing, or bay shutter open sensor was not detected within "shutter_delay" while opening. If opening when this error occurs then the firmware will close it again, (set verbose 1 for message)

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:36 2002 PST