Error Number: 15173


Error Message:

ALE: timeout moving unload cylinder


Applies to:

  • Platesetter_3244

Service Information:

  1. Check that the unload sensors indicating Extended (lowered) is working.
  2. as for 1.
  3. Check that the unload sensors indicating Retracted (raised) is working.


Operator Action:

Resume. Call Creo service if problem persists.


Cause:

  • When the unload cylinder is raised during an unload, if the unload cylinder has not left the lowered (extended) position within unload_delay seconds then this error is generated.
  • In the ale_lower_unload() function the error is generated if the unload cylinder has not arrived at the lowered (extended) position withing unload_delay seconds. ale_lower_unload() is used during initialisation, unload, process and time table.
  • In the ale_raise_unload() function the error is generated if the unload cylinder has not arrived at the raised (retracted) position withing unload_delay seconds. ale_raise_unload() is not used as this time.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page