Error Number: 15182


Error Message:

ALE: plate on picker, remove plate from unload ramp


Applies to:

  • Platesetter_3244

Service Information:

  1. Proximity sensor failure.
  2. Vacuum sensor failure.


Operator Action:

Remove plate from picker or select resume or clear.


Cause:

  • This error is generated if there was a plate detected on the picker in one of the following scenarios: - Detected by VACUUM
  • Before beginning the "process" sequence the process status is checked: If a plate is detected on picker by picker vacuum above threshold or if the picker plate_loc status flag does not show "picker empty". then this error is reported and the plate cannot be ejected to processor as another plate is hanging on the picker. - Detected by the PROXIMITY DETECTOR,
  • During a ale_pick_status_ok check which is performed before a pick is started (pick0)

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page