Error Number: 15191


Error Message:

ALE: Picker could not locate the bay detect tab in cassette bay %d


Applies to:

  • Platesetter_3244

Service Information:

Open machine and check position of Picker. check PY pos.


Operator Action:

Resume. If that is not sucessful, reset.


Cause:

  • The ale drv task continually checks the progress of a stepper that has been started to move to a position, if an event flag is set to stop the stepper on, for example, a bay tab. then the drv task will report this error if the complete distance is moved, that is if no event If the even (bay tab) is detected before the full distance is moved, then this error is reported. Check bay_location. Read: http://intranet/support/docs/ps3244_pickseq.pdf

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:37 2002 PST