Error Number: 15192


Error Message:

ALE: End of bay <bay#> detection tab not found, picker may be stuck.


Applies to:

  • Platesetter_3244

Service Information:

check bay sensor using "picker" or "sat stat pkr". check that bay tab is not damaged. check bay locations. (cal bay f/w 2.25) Replace H/A board / cables. Check for PY stalling / driver problems.


Operator Action:

Resume. If problem persists, reset machine, remove plates as required during start up.


Cause:

  • Y axis stopped because distance (btsy) was moved but never found tab.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:37 2002 PST