Error Message: |
ALE: Has plate been removed from Unload table ? Yes,Resume - No,Clear |
Applies to: |
|
Operator Action: |
To remove a plate you may do the following, 1) From the diagnostic monitor type "process", if that fails, then 2) Open the door to access the plate, type UVAC OFF 8 and immediately go and hold the plate. This will release the vacuum within 8 seconds. |
Service Information: |
This error occured if there was still a plate on the unload table during initialisation. ALE init cannot complete until all plates are removed from the picker and unloader. The plate will be dropped if "resume" is selected, it assumes that the unload vacuum threshold is incorrectly set, if it is then it will be shown up later during the ale init. After an abnormal situation, this may be reported if the plate_loc 2 (drum) status is non 0 when the load command is issued. Clicking resume will set the plate_loc d status to 0. clicking clear will abandon the "load" command. |
Cause:
|
See Also: |
|
Go to CTP Firmware Error Index Page