Error Message: |
ALE: Unload Cups timed out moving in |
Applies to: |
|
Operator Action: |
Select the RESUME button on the workstation dialog box. If this fails to correct the problem, check that nothing is obstructing the unload cups from retracting. If everything looks normal, then Creo Service should be called. |
Service Information: |
The unload vacuum cup retract sensors failed to trip within the timeout specified by the aldly ucud parameter. The sensor status may be checked by using the TABLE command. The sensor status should read TRUE if the sensors are activated. It may be useful to set the 'verbose alcmd' and 'verbose alconv' parameters to 1 in order to obtain further diagnostic information. Typing "ALE" will display the system air pressure. |
Cause:
|
See Also: |
|
Go to CTP Firmware Error Index Page