Error Number: 16010


Error Message:

IMAGE: Total mainscan shift too large


Applies to:

  • All

Service Information:

The net mainscan shift is calculated from the following parameters:

  1. "set gc mss" - nominal shift, the same for all recorders of the same model
  2. "set gc mssa" - adjustment made during integration
  3. "set mode <mode> mssa" - the workstation can overwrite this shift with a new one for each image

The values of the "gc" parameters should be compared to the factory settings. If these settings are not the problem, the workstation must have sent a large positive mainscan shift. This should be found and adjusted.

The maximum mainscan shift is equal to 4096 pixels, i.e. 2.56 inches in 1600 DPI, 1.7 inches in 2400 DPI, and 1.28 inches in 3200 DPI.


Operator Action:

Record error message and contact Creo Service


Cause:

  • "set gc mss", "set gc mssa", and/or "set mode <mode> mssa" shift parameters are incorrect
  • Workstation is specifying a large positive shift around the drum.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:48 2002 PST