Error Message: |
IMAGE: stroke flatten tolerance increased by <2,3,4 ...> |
Applies to: |
|
Service Information: |
The firmware was unable to calibrate the stroke to the tolerance specified by the "set media <media> stol" parameter, and is therefore increasing the tolerance by the indicated factor. If necessary, the tolerance will be increased up to the limit specified by the "set media <media> ltol" parameter. If the desired exposure level is reasonable, this message can indicate a failing head. The weakest pixels cannot reach the desired exposure level, so the tolerance must be increased. The DAOM calibration also may be inaccurate. |
Operator Action: |
Report this message to Creo Service. If no other errors are reported, the platesetter will continue working fine, but may need servicing soon. |
Cause:
|
See Also: |
|