Error Message: |
IMAGE: Cannot achieve desired laser power, imaging time increased by <percent> % |
Applies to: |
|
Service Information: |
This warning will only occur if media sensitivity-based wpower and drum speed calculations are enabled. If the head could not output the desired wpower, then a lower setting was used and the drum speed had to be decreased in order to compensate. This may or may not be a problem, depending how much the speed was decreased and what power level the head can still output. |
Operator Action: |
This indicates the imaging speed has to be decreased in order to properly expose the plate or other imaging media. Continue imaging with the machine, but call Creo Customer Support to let them know your machine needs a check-up. |
Cause:
|
See Also: |
|