Error Number: 16060


Error Message:

IMAGE: surface depth of %ld microns above maximum limit of 1000 microns


Applies to:

  • Thermal

Service Information:

The requested surface depth before a plot was above the upper limit of 1000 microns (um). The requested surface depth is specified in the error message.

If a sd test series plot was started or underway, the requested surface depth for the next series step was higher than the limit.


Operator Action:

Check that the correct media type was selected for the current image, then try the image again. If the problem persists, call Creo Customer Support for help.


Cause:

  • The NVS media sd setting may be too high.
  • The workstation specified a media type that was not normally used, which has a NVS media sd setting that is too high.
  • A surface depth series plot was started or underway, and the requested surface depth for the for the next series step was higher than 1000 um.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:49 2002 PST