Error Number: 16068


Error Message:

IMAGE: Unable to initialize plot for mode set to 0 DPI


Applies to:

  • All

Service Information:

A plot mode has been selected that had the "rip_dpi" parameter set to 0. Instead of crashing, this error is reported. It is generally caused by someone accidentally setting the default mode (generally mode 1) dpi setting to 0. This can also happen if a machine is configured to only support 1200dpi - any modes with resolution greater than 1200dpi may have the rip_dpi parameter set to 0.

The solution is to set the "mode dpi" parameter to a valid resolution.


Operator Action:

The device has been requested to image at a resolution of 0dpi. This is either an error in the file, or a problem with the machine. Cancel the job and try a different file. If it also fails, contact the CreoScitex Response Centre.


Cause:

  • Default mode has resolution of 0dpi.
  • Current mode has been changed so that the dpi parameter is now 0.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page