Error Message: |
IMAGE: Job failed because of error on paired plate |
Applies to: |
|
Service Information: |
An error has occurred on one plate of two, and it is un-safe to image the second plate. Most likely the firmware detected multiple plates while starting to image the first plate. It could be un-safe to spin the drum and image the second plate, so the second plate is cancelled and both plates are unloaded. |
Operator Action: |
This message should only ever appear as a warning message. It means that the second plate of two loaded onto the drum is being cancelled because of an error on the other plate. Both plates will be unloaded immediately. A typical cause of such an error would be if the device detects two plates on one side. It would be un-safe to spin the drum and image the second plate, so the second plate is cancelled and both plates are unloaded. This should not suspend operation. If this causes trouble, contact the CreoScitex Response Centre. |
Cause:
|
See Also: |
|
Go to CTP Firmware Error Index Page