Error Message: |
IMAGE: Retraces occurred during plotting - check plate for artifacts. (total number of retraces: <retraces>) |
Applies to: |
|
Service Information: |
Some media is very sensitive to retracing. If the "media x slf (stray_light_fogging)" parameter is set to 1 and retraces occurred during the plot, this error will be reported at the end of the image. Retraces are necessary if the Trendsetter runs out of data during the plot. The carriage is forced to stop and wait for more data to be sent from the rip. Resetting the entire system (Trendsetter and workstation) may help. |
Operator Action: |
Check the plate for image artifacts. Re-run the job if necessary. If the problem persists, try resetting the entire system (Trendsetter and workstation), then call CreoScitex service for assistance. |
Cause:
|
See Also: |
|
Go to CTP Firmware Error Index Page
Go to CTP Firmware Error Search Page