Error Number: 19000


Error Message:

PDB: Air Supply Below Threshold


Applies to:

  • All

Service Information:

The firmware detected that the system air supply is below the threshold specified in the NVS sys sys_pressure_thresh.


Operator Action:

Check the air hose connected to the machine and ensure that it has sufficient air pressure. Also check the threshold value specified in NVS sys sys_pressure_thresh.


Cause:

  • Improperly calibrated pressure sensor. Run cal pressure command.
  • Low or No air pressure supplied to the machine.
  • Invalid NVS value sys sys_pressure_thresh.
  • Faulty pressure sensor.
  • Leak in hoses and connection between the supply and the pressure sensor.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:54 2002 PST