Error Message: |
ALE2: Measured Main Scan Size (%d.%d\") larger than maximum allowable size |
Applies to: |
|
Service Information: |
If the machine is refusing to accept the correct size plates, check on the configuration (50x67 vs 52x80) via the following paramters: sys maxssz - Password protected encoded value for the subscan size of the machine config msz - Should be set to value to match the customers machine type (ie. 50 or 52) config ssz - Same as msz but for ThermoFlex acceptable values are 67 or 80 |
Operator Action: |
Re-submit with an acceptable sized plate. If plate dimensions are already within the maximums for your ThermoFlex then contact Creo Service. |
Cause:
|
See Also: |
|