Error Number: 22450


Error Message:

ALE2: Plate too small to run through the processor, please remove plate from unload table


Applies to:

  • Trendsetter_400/800_Auto

Operator Action:

Remove plate from unload table.


Service Information:

This error will be displayed if the plate is too small to run through the processor, that is, if the plate is smaller that the distance between the rollers inside the processor. This error is generated to prevent plates from being stuck inside the processor. Verify that the value of the nvs "al prg" is set correctly.


Cause:

  • The nvs "al prg" is not set correctly.
  • The plate is too small to run through the processor

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:59 2002 PST