NVS Parameter: al dfp


Long Name:

drum_focus_pos

Applies to:

  • ThermoFlex

  • Description:

    The head stage is used to focus the head (roughly) on the very varied thicknesses of flexo media, it is also used to measure the thickness of each plate as it is loaded so that distortion calculations can be done correctly. Also when used with a TFX head it is sent to find the position at which the laser focusses on the drum. This parameter serves to store the position at which point the TFX laser is focussed on the drum. This parameter is then used to calculate plate thickness instead of al hsap in the case of 1.7x heads. This parameter is automatically updated upon successful completion of a stage install tfx command.


    Type:

    uint32

    Default:

    • 0

    Range:

    • 0 to 5000 [steps]

    Notes:


    Partition:

    cal

    See Also:

  • Command: stage install tfx
  • NVS: al hsap

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:09 2002 PST