Description: |
Moves load ramp actuators and displays sensor status. Use with no parameters to display the sensor status. Any sensors which are masked off are listed as "disabled". The optional "w" parameter moves the specified actuator and then waits for either the associated sensor to trip or the timeout to expire. If the sensor is NOT masked off and the timeout expires before the sensor trips, a timeout message will be returned (otherwise "Command Complete" is returned). Note that the monitor is locked out for the duration of the command if the "w" parameter is used. |
Applies To: |
|
Syntax: |
ramp ramp [in|out][w] |
Notes: |
ramp - Displays sensor. ramp in - Moves both the top and bottom of the load ramp towards the drum. ramp out - Moves both the top and bottom of the load ramp away from the drum. |
See Also: |
|
Go to CTP Firmware Commands Index Page