NVS Parameter: head wkp


Long Name:

wr_laser_Kp

Applies to:

  • Thermal

  • Description:

    Specify the gains for the PID controller which sets the laser diode current.

    The error signal fed to the PID controller is the difference between the desired power (wpower) and the measured power.

    The wkp, wki, and wkd parameters specify the proportional, integral, and derivative gains respectively.

    These parameters affect the performance and stability of the laser diode servo. They should never be changed in the field.


    Type:

    real

    Default:

    • 0.350

    Range:

    • 0.000 to 60.000

    Notes:


    Partition:

    cfg

    See Also:

  • NVS: hdm wpower
  • NVS: head lsrmode
  • NVS: head wki
  • NVS: head wkd
  • NVS: head wsample

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:42 2002 PST