Dolev 4press - Installation
Setup and Configure Dolev 4press
This section explains how to verify that the CreoScitex
software versions used on the Imagesetter and on the Host are compatible,
and how to configure the Imagesetter into the Host.
Overview
Before starting work, you need to verify that
the CreoScitex software version running on the Imagesetter is compatible
with the CreoScitex software version installed on the Host PS/2*.
On the Imagesetter
During startup, the Imagesetter automatically loads its software.
The number of the currently loaded Imagesetter software version is
indicated on the Control Panels LCD screen (see Control Panel, Imagesetter Micro
Version above).
On the Host PS/2*
- On the Library screen, select Show from the Utility strip.
- Select Version Information from the Show menu.
The window that appears indicates the number and information related
to the currently installed CreoScitex Host software version (and
to software updates, if such exist).
- Select Continue to return to the Library screen.
To update the Imagesetter software, proceed as follows:
If the software versions are not compatible, you
probably need to update the CreoScitex software on the Imagesetter.
- Obtain the CreoScitex Imagesetter software
that is compatible with the CreoScitex software on the Host PS/2*.
- Ensure that the software update disk is write-protected, and insert
the disk into the Floppy Disk Drive at the Imagesetter rear (refer to the Imagesetter Rear
View figure above).
- Reset the Imagesetter before continuing (refer to the Reset section
above).
Configuring the Imagesetter into the Host
Before continuing, make sure you verified the software versions of
the Imagesetter and the Host PS/2*.
Proceed as follows on the Host PS/2*:
- On the Library screen, select Services from the Utility strip.
- Select Shut System Down from the Services menu and Shutdown on the
message which appears.
- At the Console Login: prompt, type sciutil.
The system loads the CreoScitex Utilities application.
- Select 1. Local Devices Configuration from
the CreoScitex Utilities menu.
- Select 6. Imagesetter SetUp from the Local Devices Configuration
menu.
The Imagesetter Setup window appears.
- Toggle the Device Type field to Dolev 4press.
- The Size fields indicate the height and width of the image plotting
area. Note: Although you may decrease these values to limit the plotting area, they are
overwritten when you perform Get Params from Plotter.
- Toggle the Ripping Type field to Single [the default] for the
standard work mode, or to Dual (dual RIP mode) to enable two (2) workstations to expose on
one (1) Imagesetter.
- No action is required for the Card Type field, since it should
specify VLSI at all times.
- Press <F1> (Save & Exit) to store these settings.
- Press <F8> (Quit) until you exit the
CreoScitex Utilities application.
- Load the CreoScitex Main application (refer
to Activating the CreoScitex Main Application above).
|