Dolev 4press - Installation
Imagesetter Check
A film loading cycle is performed with Imagesetter doors open in
order to provide a brief physical brief check of the Imagesetter.
Attention: In order for the
Imagesetter to operate with its doors open, you will need to ensure that the interlock
system is defeated.
In the event of Imagesetter malfunction during this check, refer to
Running Imagesetter Diagnostics.
Ensure that the dynamic optmechanical carriage moves freely and is
correctly calibrated.
- On the Imagesetter control panel, press Util. The Utilities screen
will appear.
- Select Machine. The Machine options menu appears.
- Select Carriage and press <Enter>.
- Select Move to End Position and press <Enter>. The carriage
will be moved to its end position. When movement is complete, the message PASS should
appear at the extreme right of the data line at the bottom of the monitor.
- Return to the Machine options menu once again. Select Carriage and
press <Enter>.
- Select Calibrate Home Position and press <Enter>. The carriage
will return to its home position. When calibration is complete, the message PASS should
appear at the extreme right of the data line at the bottom of the monitor.
Ensure that the spinner is operating according to required
specifications.
- From the Utilities screen select Machine. The Machine options menu
appears.
- Select Spinner and press <Enter>.
- Select Start Spin and press <Enter> The spinner will begin
spinning. The message PASS should appear at the extreme right of the data line at the
bottom of the monitor.
- Return to the Machine options menu once again. Select Spinner and
press <Enter>.
- Select Stop Spin and press <Enter> The spinner will stop
spinning. The message PASS should appear at the extreme right of the data line at the
bottom of the monitor.
Ensure that the laser is operating according to required
specifications.
- From the Utilities screen select Machine. The Machine options menu
appears.
- Select Laser and press <Enter>.
- Select Create NDF Graph and press <Enter> The Imagesetter will
activate the laser and perform a series of programmed steps in order to create an
analytical graph.
The laser
light is active with access doors open during this step. Take the
appropriate precautionary measures to protect both yourself and
others in the Imagesetter installation area.
Immediately following these programmed steps, the graph will be
displayed, showing laser intensity.
- To exit the graph, press <Enter>.
|