Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Field Change Order
Dolev 4Press - FCO 21611- Unloading light seal.
| Description The light seal door limit and the unloading cassette plunger house are replaced to improve the film flow to the accumulative cassette. |
News Version: 45
| Prepared By: A. Posner | FCO Kit No.: 510F21611 |
| Comp. Level: N/A | Machine S/N: Lower than 9546xxxx |
| Catalog No. N/A | S/W Affected: N/A |
| Type of Change: Conditional | Total Number of Pages: |
| Product Mgr: K. Paperny | Approval Date: 12/20/95 |
| Product Support: S. Amit | Approval Date: 12/17/95 |
| Customer Support Mgr: S. Cohen | Approval Date: 12/20/95 |
1. Reason for Change
The door limit on the unloading light seal and the plunger on the cassette can cause problems in the film flow to unloading cassette.
2. Description of Change
Replace the two door limits on the light seal and the plunger housing on the accumulative cassette.
3. Change Procedure
3.1 Remove the unloading light seal from the imagesetter
3.2 Remove the door limit (#2 in drawing 732C7G117)
3.3 Install the supplied 2x Door Limit II
3.4 Re-install the unloading light seal, making sure that it is positioned correctly on the two side flanges.
3.5 Remove the plunder housing from the unloading cassette (# 19 in drawing 732D6G053)
3.6 Install the supplied plunger housing II
3.7 Insert the cassette into the unloading drawer.
4. Test Procedure
4.1 Run film from the loading cassette to the unloading cassette and verify good operation.
4.2 Test the film flow at least 5 times at least.
5. Parts List
2x 280B40733A Door Limit II
1x 290B39894A Plunger House II
6. Attached Documentation
Drawing 732D6G053
Drawing 732C7G117
7. Material Disposition
The old material can be discarded
8. Logistics
Material for the FCO will be supplied one month after order placement.
| Subsidiary | No. of kits which may be ordered |
| STA | up to 15 kits |
| STE | up to 35 kits |
| STMA | up to 2 kits |
| STN | up to 2 kits |