Author/Submitter: A. Posner (02/13/96)
Document Released: 02/13/96
Product Family: Imagesetters / Platesetters
The new board HOMC2 ( Cat Number 503C42273 ) replaces the
board HOMC. The Effectively date for the new board is
April 1, 1996 .
The reasons for the replacement are:
The new board is functionally equivalent to the old one.
The new board has to be operated with the following s/w :
If the HOMC2 board is operated with lower version, 2 error messages appear:
These messages has no influence on the machine operation and they arise due to the voltage measuring s/w algorithm. This algorithm was changed in the higher versions.