Dolev 4Press/news - "TP SOL Overload" Error Message 


Product

  Dolev 4Press/news

Component

 

Interlock switch on the left side door 


Error

 
  • TP SOL overload
  • LDM motor overload
  • CUTM motor overload

Symptoms

 

The tail punch sol overload error message appears, sometimes accompanied by the cutter motor and load motor overload error messages.


Cause

  A loose wire on the interlock switch on the left side door disabled the 12 volt supply during operation.

Solution

 
  1. Operate the plotter with the side doors open.
  2. Check whether the 12 volt LED on the DC motor controller board is flickering on and off.
  3. If the 12 volt LED is flickering, secure all wires on the interlock switch.

Technical contact(s)
 

Oded Zaccai

Submitted by
 

Steve Buttrick

Date submitted
 

09 Oct 2002