Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Dolev 800/800V/800VČ - Brisque Application Issues
Updating the Cassette NVM
Cassette "Sign In"

Whenever you mount a new supply cassette on the imagesetter, you must "Sign In" your cassette. Sign In includes recording the type of media, manufacturer, batch number and the length of media on cassette.

The information is used to automatically select the correct exposure values for your specific media type. It is very important that you provide as much information as possible about the cassette media. Once you record this information, it is stored on the cassette and used during media exposure.

You have the additional option of accessing the control panel functions from a CreoScitex I/O workstation.

  1. Press F2 UPDATE on the imagesetter control panel.

  2. Select the cassette you are registering, SML, MED, LRG. Select the media, film, paper, or polyester plate. Select the media thickness, 4 mil or 7 mil.

    Note: The media catalog number contains the code for the media thickness.

  3. Register the initial length of the media on the cassette. If the cassette contains less than a full roll of film, check that the correct length appears in the parameter.

  4. Select the Vendor (manufacturer).