Dolev 800/800V/800VČ - Brisque Application Issues
Class Screening
Workflow for Application
Proof (analog)
Conventional
Geometric Dot
HDP
FullTone
| Exposure time (check on Microline control step) | Vacuum Duration | |
| Positive & Negative | As recommended by themanufacturer | Standard for the used proof method |
| Exposure Time (check on Microline control wedge) | Vacuum Duration | |
| Positive & Negative | As recommended by themanufacturer | Standard for the used proof method |
| Exposure Time (check on control wedge) | Vacuum Duration | |
| Negative | As with material exposed at 175-200 lpi
(70-80 l/cm). It may be needed to decrease exposure by 10-15% depending on film contrast. |
Follow manufacturer instructions. |
| Positive | Mesh (Screen Ruling) 2 50 (100 l/cm) 10-11 300 (120 l/cm) 10-11 400 (160 l/cm) 6-8 500 (200 l/cm) 6 600 (240 l/cm) 6 |
Microline Standard X 1.5 approx. |
| Exposure Time (check on control step) | Vacuum Duration | ||
| Negative | As with material exposed at 175-200 lpi
(70-80 l/cm). It may be needed to decrease exposure by 10-15% depending on film contrast. |
Follow manufacturer instructions. |
|
| Exposure Resolution (Laser dots/mm) | Microline | Vacuum Duration | |
| Positive | 60 80 100 120 140 |
12+ 8-10 6-8 6 6 |
Standard X 1.5 approx. |