Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Dolev 800 - Brisque Application Issues
Class Screening
Worflow for Application

Plate Making

Conventional
Geometric Dot
HDP
FullTone

Conventional

Mesh (Screen ruling) Exposure Time (check on control step) Vacuum Duration
65-200 Sufficient to achieve 11 - 15
microns depending on the job type
As recommended by manufacturer

Geometric Dot

Mesh (Screen ruling) Exposure Time (check on control step) Vacuum Duration
65-200 Sufficient to achieve 11 - 15
microns depending on the job type
As recommended by manufacturer

HDP

Overview
Tips

Overview

  Exposure Time (check on control wedge)   Vacuum Duration
Negative As with conventional Screen Rulings
(175-200 lpi or 70-80 l/cm), you may need to
decrease exposure by 10-15%,
depending on the film contrast.
  Standard X 1.5 Apx.
  Screen Ruling Microline Standard
Positive     X 1.5 Apx.
  250 8 -10  
  300 8- 10  
  400 6 - 8  
  500 6  
  600 6  

Tips

FullTone

Overview
Tips

Overview

  Exposure Time (check on Microline control step)   Vacuum Duration
Negative As with conventional Screen Rulings
(175-200 lpi or 70-80 l/cm), you may need to
decrease exposure by 10-15%,
depending on the film contrast.
  Standard X 1.5 Apx.
  Res Microline Standard
Positive 60 12+ X 1.5 Apx.
  80 8- 10  
  100 6 - 8  
  120 6  
  140 4 - 6  

Tips


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.