These release notes describes the changes and additions that have been made
to the Dolev® 800 family since software version 1.060. The release
notes describe the new features, known problems, and installation instructions
for version 1.062.
Products affected
Dolev 800V+
Dolev 800V2
Dolev 800V3
New features
Error mechanism in multi-tasking modenotifies the host which task,
if any, failed during plot sequence
Task Queue for CS Xposeimproves the communication logic between the
plotter and the host(s)
Improved program code for OMC board for improved roller movement
Spinner startup timeout expanded to enable more time for spinner setif
the task fails, the plotter makes a second attempt to reach the desired spinner
rotation speed
Auto cassette sequence improvedif the user selects Auto Cassette
and the task fails, the plotter tries to work with another cassette without
cancelling the exposure
Feeder offset and roller offset are now independant of each other
Known problems
OMC board comp level configurationin Service Operation mode, all levels
under level M are identified as K
Installation
There is a difference between the format of information files
contained in the Software Machine Parameters prior to, and after, version 1.060.
Updating from earlier versions to version 1.060 or higher changes the old save
format to the new save format.
For versions earlier than 1.060, follow these instructions
to ensure the smooth transition to version 1.062 or higher.
Verify that the existing version works properly.
Save all parameters to a Software Machine Parameters (501V1M353) diskette.
This diskette is effective for versions earlier than 1.060, and is necessary
if you want to reinstall the earlier version.
Write down the media information for all three cassettes on paper.
Install the new software.
On the first startup, a fatal error appears. Ignore it.
Manually restore the media parameters that you recorded in step 3.
Adjust the values of the feed and roller offset
parameters. This prevents the error message Roller not at Safe Position.
Save all the parameters to a new Software Machine Parameters diskette. (This
diskette is effective for versions 1.060 and later).
Notes
Version 1.062 is compatible with all workflow types except for Dolev
800 V+ and V2 when they are defined as Bitmap and used with one of the following:
Founder Eagle RIP
Dolev TIFF expose
With either of these configurations, use version 1.034.
To return to an earlier version, delete the contents of the Setup
directory under C:\PLOT\SETUP, and then, after installing
the earlier version, use the Software Machine Parameters diskette to restore
all previous parameters.
After installation, you must adjust the feed and roller offset values, even
if you are updating from version 1.060 or higher. See step 7 above.
Popups / Tool Tips for this Page
The
Offset parameters are located in Machine Settings>Offsets.
Popups / Tool Tips for this Page
To
change the Idle Spinner Rotation option, select Tools
operations > setup > service tables
> machine settings. To prevent the spinner from