Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Prepared By: A. Posner
December 7, 1993

FCO #18638 Data Unit Crate (800/800)

Reason for Change                        
                   

During plot an error message of illegal stop spiral will stop the exposure and the plot will aborted.       
       

A better grounding of the cable shield is needed.

Description of Change                        
                   

The Data cable inside the Data unit should be replaced with a new one with an addition of ground in both sides of the cable.   


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.