FSB 280 - UPDATING STROBE 5 AND OMC BOARDS IN
THE FIELD.
12-NOV-92
Overview
STCL recently published two FCO's concerning the Strobe 5 and
OMC boards.
For Strobe 5 board, FCO no. 16850. Its purpose is to:
a. Prevent PLL locking problems at start of plot by limiting minimum VCO input voltage to
2V at a low range and 4.5V at a high range.
For OMC board, FCO no. 16660. Its purpose is to:
a. Improve A/D precision for light calibration.
b. Add GND connection between OMC board and data cable to prevent false cable effects.
c. Change Data Channels PAL U609 to enable connection of Data B (another host) as well.
Both FCO's ask you to replace the boards with new boards
having different comp. levels.
However if you need to perform these FCO's and you cannot get
immediate replacements, you can perform part of the changes in the field.
The following explanation describes the minimum changes that
the board can undergo in order to solve the problems described above.
(Do not change the comp. level of the boards.)
STROBE 5 (503D2753)
The Problem
Shifts on the start of plot or on the gray scales area.
Corruption of the exposed file. The red led (of the PLL
unlocked) on the Strobe 5 board lights up in a bright color all through the exposure.
The Changes (see the attached scheme)
Disconnect, on the print side of the board, DZ2 (the side that
leads to R102).
Connect, on the print side of the board, resistor R100 (20K)
between the disconnected pad of DZ2 and the disconnected pad of resistor R102.
Connect, on the print side of the board, diode CR1 (1N914),
the catode to R102 (the disconnected pad) and the anode to U102-1.
Connect, on the print side of the board, diode DZ6 (1N5222B)
130B02500 the catode to U101-1 and the anode to anode of the diode CR2 (1N914) cat. no.
130A07500. Connect the CR2 catode to TP7.
Test Procedure
Run diagnostics on the Strobe 5 board and check that all tests
pass.
Expose several files and check that the problem doesn't
reappear.
OMC BOARD (503D28273)
(You can perform the following changes separately according
to the problem.)
The problem
If you want to enable data port B for PS/2.
The change
Replace PAL (U609) cat. no. 107K8A434 with PAL (U609) cat.
no. 107K8A434A.
Test procedure
Connect the PS/2 data cable to port B and try to plot from
PS/2. Check the exposure for acceptable results.
The problem
Problems with lines on exposure due to distortion in the
information passing the data cable.
The changes
Disconnect J1-1 in the print side of the board.
Disconnect J2-1 in the print side of the board.
Connect J1-1 to J2-1 and to the DGND U807-10.
Test procedure
Run diagnostics and verify that all tests pass.
Expose several files and check if the problem disappears.
The problem
Light stability between different exposures with same
calibration value.
The change
Replace capacitors C110, C108 from 0.1æF (cat. no. 151K41001)
to 100 PF (cat. no. 151K11001).
Replace capacitors C101, C106 from o.047æF (cat. no.
151K34701) to 33 PF (cat. no. 151K03301).
Test
1. Expose a few files and check for no density variation
between the files.