Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
The new Microversion 7.04 supports all the
Dolev 800V family and works with all the front-end platforms.
This new version replaces the official version 5.66.
Important Note: The imagesetter tables might be changed in this version so, it is
important to save all the machine parameters on a backup diskette and on hard copy!
New features and fixed bugs are described in this document.
- Rename the version number for Dolev 800 V series to prevent possible mistakes in Dolev 800 and Dolev 800 V S/W recognition.
- Add support for DOLEV3136V version and Increase max. film feed for model Dolev 3136 to 980 mm.
- Ignore the error in "Home Position" carriage calibration when no punch system is enabled.
- Add new "Conveyor Delay Time" parameter for precise conveyor take film adjustment. This delay will not stop the conveyor but will push the film more to the bridge.
- Fix protocol version autorecognition bug.
- Improve SSP logic in last two plot lines.
- Fix bug in the large cassette display even when the cassette was out.
- Solution for COARSE CALIBRATION Error.
- The intensity strips will start at 100 with steps of 10 instead of 300 and steps of 100.
- Save all the Dolev 800V tables on a backup diskette.
- Insert the supplied diskette and reboot the machine. The Dolev 800 is updated with the new version that is loaded on the Dolev 800V by booting from the new diskette.
- Save parameter again on the system diskette.
- After loading ver. 7.04, check that the Dolev 800V is in standby mode.
- Plot full size format to check that there is no image corruption.
- Verify that all the parameters are as before. Make sure that the Processor delay is set to 0.