Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
When the Whisper is connected to DOLEV 800 running ver 5.xx in a DUAL SFL configuration it MUST be connected With Two (2) cables. One cable is the SFL cable going to the VLSI, and the other cable is the CONTROL (rs232) cable going to COM1 or COM2 on the CPU board. The best is to have the WHISPER RS232 connected to COM1 and the data cable coming from the VLSI to COM3. The panel is connected to com2. (It is possible to put the panel on COM1 the WHISPER RS232 on COM2 and the data from the VLSI on com4)
The Whisper versions are 8.2.RL3 and up or 7.xx+UPDT_PLT_45D.
The HOST SPARE FLAG in PLOTTER SETTING must be 1025 for the RS232 configuration.