Save all parameters to a Software Machine Parameters diskette (part
number 501V1M353). This diskette is effective for versions earlier than
1.060, and is necessary if you want to reinstall the earlier version.
Write down the media information for all three cassettes on paper.
Install the new software.
On the first startup, a fatal error appears. Ignore it.
Manually restore the media parameters that you recorded in step 3.
Adjust the values of the feed and roller offset
parameters. This prevents the error message Roller not at Safe
Position.
Save all the parameters to a new Software Machine Parameters diskette.
(This diskette is effective for versions 1.060 and later).