Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
|
||
Platform |
Brisque F50 and Brisque Tiger II |
||
Component |
Carriage motor |
||
Error |
|
||
Symptoms |
The imagesetter did not start imaging after loading the film. After a while, jobs are missing and there is blank film in the output tray of the processor.
|
||
Cause |
Due to a faulty carriage motor connector, the carriage does not move, so the stepper driver counter does not transfer information to the CRI board. Without the infromation from the stepper driver counter, the device cannot release data from the buffer so the buffer becomes full. |
||
Solution |
Repair the harness connector and replace the stepper motor assembly if required. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
24 Oct 2004 |
||