Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Error message “TSP buffer full while waiting for Dolev” on Brisque for Dolev 800


Product

 
  • Dolev® 800V
  • Brisque® Workflow Solution version 4.0
  • Brisque version 4.1
  • Brisque version 5

Platform

 

Brisque F50 and Brisque Tiger II


Component

 

Carriage motor


Error

 

TSP buffer full while waiting for Dolev


Symptoms

 

The imagesetter did not start imaging after loading the film. After a while, jobs are missing and there is blank film in the output tray of the processor.

 


Cause

 

Due to a faulty carriage motor connector, the carriage does not move, so the stepper driver counter does not transfer information to the CRI board. Without the infromation from the stepper driver counter, the device cannot release data from the buffer so the buffer becomes full.


Solution

 

Repair the harness connector and replace the stepper motor assembly if required.


Technical contact(s)
 

Oded Zaccai

Submitted by
 

James Fendler

Date submitted
 

24 Oct 2004


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.