Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Diagnostics tests fail on Dolev 800 V3 with Advantech CPU-486


Product

 

Dolev® 800 V3


Component

 

Advantech CPU-486


Symptoms

 

Following the replacement of the CPU, several diagnostics tests fail.

The following tests are known to fail:

  • ACRI - OFF LINE - 196 PERIPH - Timer
  • ACRI - OFF LINE - PLL CLOCK - Pll Clock
  • ACRI - OFF LINE - PLL CLOCK - Pll Div Clk
  • ACRI - OFF LINE - REAL M.STEP - Micro Step
  • ACRI - OFF LINE - REAL M.STEP - Acc Request
  • ACRI - OFF LINE - REAL M.STEP - Stop Cond
  • DRIVERS - RELAY 2

Cause

 

The faster CPU causes changes in timings.


Solution

  Before running the tests, from the Flags menu, select Assistance by clicking FA<CR>.
This causes all tests to run more slowly to compensate for the CPU speed.

Technical contact(s)
 

Oded Zaccai

Submitted by
 

Ido Regev

Date submitted
 

06 Oct 2005


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.