Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Misregistration Occurs and Image is Out of Focus on Dolev 800 V3 with Software Version 1.062


Product

 

Dolev® 800 V3 with software version 1.062


Symptoms

 

Misregistration occurs and the image is out of focus on Dolev 800 V3 with software version 1.062.


Cause

 

In the entrance to the drum, close to the feeder rollers, the film is not completely attached to the drum.

 


Solution

  Uninstall microversion 1.062 and install microversion 1.058 (see the Downloads page).

Technical contact(s)
 

Oded Zaccai

Submitted by
 

Oded Zaccai

Date submitted
 

26 Jan 2006