Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
|
||
Machines affected |
All devices with MPE firmware |
||
Symptoms |
On positive plates, for some plate sizes, a 0.5-1.0 mm strip is unimaged on the away side of the plate. This artifact has been seen after firmware upgrades on Trendsetter VLFs and Trendsetter Spectrums, but it probably affects all MPE devices. |
||
Cause |
Not yet known; under investigation by the Firmware Engineering team. |
||
Solution |
Solution: The only known solution is to downgrade to an earlier version of MPE firmware. Workaround: A possible workaround is to increase the plate subscan size definition in the device control software (e.g., Print Console), generate a new PPD, and re-align the image in the imposition software to re-center the image on the plate.
If you must upgrade firmware because you are replacing a thermal head, or for some other reason, you will have to submit customer jobs for every size of positive plate to verify that the artifact is not seen on any size. Keep in mind that even if every plate you test is unaffected after the firmware upgrade, the next batch of plates might be slightly bigger and the problem could appear. Be prepared to downgrade the firmware if the artifact appears and the customer is not willing to consider the workaround. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
15 Jul 2002 |
||