Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


FCO 512-29088 - Y connector for air pipes

Applies to

  Lotem™ 400 family
  • Lotem 400
  • Lotem 400 (small)
  • Lotem 400 with MCU
  • Lotem 400 with PS/M

Priority = Next visit
Release date = 01 Sep 2002
Type of change = Conditional

Component

  Y connector

Problem

 

Air pipes do not connect tightly to the Y connector.

Solution

  Remove the Y connector and install revised Y connector (P/N 344D57020).

Time needed to implement

 

1 hour

Parts needed

 

P/N

Qty

Part name

344D57020 6 Y connector
719-29088 1 FCO document

Procedure

 
  1. From the Lotem application, open the rear door, and then shut down the machine.
  2. Disconnect the air pressure.
  3. Open the right side door, and then open the light cover.
  4. Disconnect each of the six Y connectors from their air pipes. 
  5. Connect the new Y connectors (P/N 344D57020) to the air pipes, fitting the air pipes into (instead of over) the Y connector.
  6. Close the light cover, and then close the right side door.
  7. Connect the air pressure.
  8. Close the rear door, and then turn on the machine.

Logistics

 

Approved quantities:

DU

Qty

CAM:

20

CEU:

20

CAP:

8

CJP:

5

CMA:

5

Other:

 

No Limit:

 

Material Disposition

 

Dispose of old Y connectors (P/N 344D71100).


Technical contact
 

Mario Amir

Product Support Manager: Haim Vaknin
Approval Date:

Date submitted
  01 Sep 2002

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.