Background |
|
Important Notes:
- The software installation procedure is printed on the CD cover.
- The factory-set parameters of each new machine are saved on the Machine
Parameters diskette, which is attached to the E-box.
- Save the machine parameters onto the diskette frequently, so
that they are available in case of a system crash.
- Both the Registry file and DataBase folder
can be saved on the same diskette.
- If the system disk crashes or the software is corrupted, you cannot
open the machine doors or backup the parameters. In such an event, follow
these instructions:
- To open the doors manually, refer to Removing Shipping Safeguards
in the Hardware Installation Guide for Lotem 400.
- Restore the machine parameters, using the machine parameters saved
on the diskette.
- Obtain the IP Address from the system administrator or
from Brisque® Scismit.
|
Procedure |
|
- Turn on the Lotem 400 platesetter, and start Lotem Controller.
- Manually open the right side door of the platesetter.
- Insert a formatted write-enable diskette into the floppy diskette
drive.
- On your PC, select Start > Run.
In the Run dialog box, type regedit, and click OK.
- From the Registry menu, select Export Registry File.
- Save the registry file on the diskette.
- From the Registry menu, select Exit.
- Leave the diskette in the diskette drive for saving the DataBase folder.
- Confirm that the write-enabled disk is in the disk drive.
- In Windows Explorer, browse to the DataBase folder:
C: > Lotem > Lotem400 > DataBase.
- Copy the DataBase folder, and then save it on the diskette.
- Close Windows Explorer, and remove the diskette from the diskette
drive.
- In Windows Explorer, select Start > Settings >
Control Panel.
- In the Control Panel window, select Network.
- In the Network dialog box, click the Protocols tab,
and then double-click TCP/IP address.
- Write down the IP Address.
- Click OK twice, and then close the Control Panel.
- Turn on the platesetter and open the CD drive.
- Insert the following software in the relevant drive:
- Software Startup diskette
- Operating System CD
- Press <Ctrl><Alt><Del> to start
Lotem Controller.
- Press <Delete> to enter the BIOS Setup screen.
- Select Default screen, and then select Original.
- At the prompt
Restore Old Values?, click No.
- Select Setup screen, select Advance, and change the
Boot Up Sequence to A, C, CDROM.
- Press <Esc> twice to exit, and then select Save Changes
and Exit.
The system restarts from the software startup diskette.
- From the dialog box, select Option A.
- At the prompt
Are you sure you want to continue? click
Yes. The estimated loading time 5 minutes.
- Upon completion, remove the software startup diskette from the diskette
drive and the Operating system CD from the CD drive.
- Press <Ctrl> +<Alt>+<Del> to
start Windows, and make sure that the Windows 95 software is running.
- Type the Lotem Controller IP address.
You are now ready to install the Lotem Controller and Diagnostics applications.
- If you are installing only the Lotem Controller application, delete
the Lotem400 and the Lotem400 Diag icons.
- Insert the Lotem Controller CD into the CD drive, and wait
for the Lotem Setup dialog box to appear.
- In the Installation Warning dialog box, click Next.
- In the Welcome dialog box, click Next.
- Select Yes to confirm the Software License Agreement.
- Enter the customer information as follows, and then click Next:
- Name: Lotem
- Company: Creo
- Serial: (Lotem 400 device serial number)
- In the Choose Installation Folder dialog box, verify that the destination
folder is C:\Lotem, and click Next.
- In the Setup Type Options dialog box, verify that the Setup
type is Typical, and click Next.
- In the Start Coping Files dialog box, select Next.
(The estimated loading time is 5 minutes).
- In the Welcome - Lotem 400 Setup dialog box, click Finish.
The Lotem400 and the Lotem400 Diag icons appear on the Windows 95 screen.
- Remove the Application and Diagnostics software CD from the
CD drive.
- Proceed with the Restore procedures, following.
If necessary, close the doors and start Lotem Controller by double-clicking
the Lotem400 icon.
- Insert the Machine Parameters diskette into the diskette drive.
- Select Start > Run.
- In the Run dialog box, type
regedit, and click OK.
- Select HKEY_LOCAL_MACHINE > SOFTWARE > CreoScitex > Projects
> LOTEM 400.
- From the Registry menu, select Import Registry File.
- Browse to the A drive, select the saved registry file, and then click
Open to load the registry file.
- At the prompt
Information in A:\xxx.reg has been successfully
entered into the registry., click OK.
- From the Registry menu, select Exit.
- Leave the diskette inside the diskette drive for restoring the database
folder.
- Make sure the Machine Parameters diskette is in the diskette
drive.
- In Windows Explorer, select and open the C drive.
- In the A: floppy drive, browse to the database folder, and
then copy the database folder to C:\Lotem\Lotem400.
- Select Yes to all to confirm the folder replacement.
- Select File > Close.
- Remove the diskette from the floppy drive and attach it to the electronic
box.
|