Note: The calibration of the Width Start Image Area and Height
Start Image Area parameters and the parallel spoilers is essential for correct
expose results and proper exploitation of the edge detection system.
Update 1 resolves the following issues:
Edge detectionamong the factors that lead to edge detection problems
were the following:
The location and width of strips 1 and 2 were not precise.
The System was sensitive to inconsistancies in the power supply.
Support for MCF2 board, comp level R and earlier, including MCF1.
Windows error message during shutdown in the Lotem 400 Xpose with UDRC configuration
Update 1 includes the following functionality:
Strips 1 and 2 are automatically defined.
The Drum power calibrationvalue is improved to make the system
less sensitive to power supply inconsistancies.
Note: You can order Update 1 for Version 1.60.09 on CD, part number
633-00261A.
Insert the Update 1 CD in the CD drive. The update self-installs.
After installing Update 1, from the Registry, select IO OBJECTS\Plate Edge
Detection System and change the Wide Range Search parameter value from
0 (default) to 1.