Software Downloads
Version 1.30.04 is the latest version for the Lotem 400 and Lotem 400 w/ MCU
.
When used in the Multi Cassette configuration few bugs/problems may occurred
- please find below a summery
of all known issue and how to solve them .
Before loading starts close all open application and windows on you PC (including Windows Explorer)
A configuration window will show up during the loading - you do not need
to open the machine covers to check each
board revision > the application takes it automatically from the existing
registry .
Another way is to download the attached Registry file (changed the name
back to Patch1RegistryUpdate.Reg)
and put it into the Lotem with diskette > double click on the file and
it will correct all necessary parameters to default .
Patch Registry update (in text format)
The following values should NOT be like the default :
Paper/Plate On Disposal Detector - change the Open to "0".
Centering Speed Value For Second detector - should be "15"
Min Plate Height For Operate All Valve (mm) - should be "810"
Min Plate Height For Operate Middle Valve (mm) -should be "610"
Min plate Height size for centering wait distance - should be "700"
Air Lens Suction Enable - should be set = "0"
FUFU will be always open > change to Open =0
Conveyor setting will go back to default - have to changed them back to
original
All Communication ports should have Hardware flow control = "0"