Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Lotem 400/Flexo - Laser Interlock Errors


Product

  Lotem 400

Machines affected

 
  • Lotem 400
  • Lotem 400 Flexo

Component

 

Fuse


Error

 

Laser Interlock errors


Symptoms

  The Power-On switch LED does not turn on.

Cause

  A fuse has burnt out.

Solution

 
  1. Power down the Lotem 400.

  2. Open the rear panel of the distribution box.

  3. Remove the old fuse from the transformer, as shown below.

  4. Insert a new 250V 10A fuse.

    Important: Be sure to use a 250V, 10 amp fuse. Using a different fuse may result in damage to the device.

  5. Close the rear panel of the distribution box.

  6. Power up the machine.


Technical contact(s)
 

Mario Amir

Submitted by
 

Efraim Eller

Date submitted
 

15 Apr 2002


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.