Lotem 400 with Xpose and UDRC - Error Messages Upon Startup


Product

  Lotem® 400 with Xpose and UDRC configured

Error

 

UDRC error: Unknown error message.


Symptoms

 

Upon Startup, the error message appears.


Cause

  Incorrect parameters in BIOS and in Ports

Solution

 

Change the following Bios and Ports parameters:

BIOS

  1. Reboot the PC.
  2. Access BIOS.
  3. In BIOS, select PCI/PnP, and then select IRQ10.
  4. In the Options dialog box, select ISA/EISA.
  5. Save your changes and exit BIOS. The PC automatically reboots.

Ports

  1. Select Start>Settings>Control Panel, and then double-click Ports.
  2. In the Ports dialog box, click Add.
  3. In the Advanced Settings for New Port dialog box, make the following changes:
    • COM Port Number—select 6
    • Base I/O Port Address—type 168
    • Interrupt Request Line (IRQ)—select 10
  4. Click OK.
  5. Click the Restart Now button.

Technical contact(s)
  Mario Amir
Submitted by
  Oren Adato
Date submitted
  18 May 2003