Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Lotem 400 with PS/M - SxMx Expose server is down


Product

  Lotem™ 400 with PS/M

Error

 

SxMx Expose server is down


Cause

 

Production Manager data base may be corrupt.


Solution

 

Replace the corrupt database, as described in Lotem Expose or Production Manager Does Not Launch.

If the error message persists, continue as follows:

  1. Uninstall the Lotem Expose application, and then reboot.
  2. If the following registry entry exists, delete it. HKEY_LOCAL_MACHINE\SOFTWARE\SCITEX\SEXStation
  3. If the LotemExpose folder exists under the C drive, delete the folder.
  4. Install Lotem Expose, and install any mandatory patches.
  5. Perform Lotem Expose config with the Lotem PC Controller (See Launching Lotem Expose with Lotem PC Controller.)
    Note: It is recommended that you manually restore settings; do not use the Config Restore option.
  6. Reboot.
 

Technical contact(s)
 

Mario Amir

Submitted by
 

Efraim Yosef

Date submitted
 

05 Feb 2003


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.