Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Error message “DDB OPCOD83” appears and Put and Get do not succeed on Lotem 400 and 200K


Product

 
  • Lotem® 400
  • Lotem 400 Xpose
  • Lotem 200K

Error

  DDB OPCOD83

Symptoms

 

When starting the Controller application, Put and Get actions do not succeed and the DDB OPCOD83 error message appears.


Cause

 
  • One of the doors is open when starting the application
  • The BIOS setup is not current
  • The NUC board comp level is not current
  • The .hex file is not current

Solution

 
  1. When starting the application, verify that all doors are closed.
  2. Verify that the BIOS setup is current and update the BIOS if required. (See the relevant downloads page in TechPlanet.)
  3. Verify that the NUC board is comp level N or higher and replace the NUC board if required.
  4. Rename the following files:
    • ddb-wcs.hex (Lotem400\UpLoadFile\DDB\TSP)
    • mem_mod0.rbf (Lotem400\UpLoadFile\DDB\VLSI)
    • mem_mod1.rbf (Lotem400\UpLoadFile\DDB\VLSI)
  5. Install the following files in place of the respective files in step 4.

Technical contact(s)
 

Mario Amir

Submitted by
 

Mario Amir

Date submitted
 

15 Dec 2004


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.