Diagnostics Do Not Load Properly


Product

 
  • Lotem™ 400
  • Lotem 400 PSM
  • Lotem 400 Quantum

Note: This tip applies to version 1.50.08.


Error

 

Loader Local 3 cannot be opened from diagnostics


Symptoms

  • Diagnostics do not load properly
  • During start up, a message appears, stating that the screen configuration could not be detected (VLSI,TSP), even though TSP = 1 is set in the registry.
  • The error message in the previous section appears on a manual loading machine.
  • The Local 3 board is defective (Application line not active).
    When running diagnostics with this board, two error messages appear: a C++ error message, and a message that MCF and Slave Sproc are not working.

Cause

 

The Open field in the registry for the Local Loader is missing.


Solution

 
  1. Install the correct Open registry file (download).
  2. In the registry, set the Open parameter as follows:
    • Manual machine—set Open to 0.
    • MCU—install the registry, and then set Open to 1

Technical contact(s)
 

Mario Amir

Submitted by
 

Avi Omrad

Date submitted
 

12 Feb 2003