Drum Driver 2 LEDs Status on Lotem 400

LEDs indications when ON:
- PWR SUPPLYall power supplies are functioning (P15V, N15V,
VCC, PWR15V).
- OVER VOLTthe DC bus voltage exceeds the limit (403 Vdc).
- SHORTthe motor phase shorts (phase to phase or phase
to GND/CGND) and the current exceeds 40 Amp.
- UNDER VOLTthe DC bus voltage is under the limit (100
Vdc).
- OVER LOADthe current command remained at 16 Amp. for
more than ~20 seconds, or more than 30 Amp. for more than ~10 seconds.
- INHIBITthe driver is shutdown or disabled.
- OVER TEMPthe heat sink exceeds "work temperature"
(75°).
The FAULT led is ON when any one of the following four signals
is ON:
- OVER VOLT
- UNDER VOLT
- SHORT
- OVER TEMP