Lotem 400 - loading motor reliability


Product

 

Lotem™ 400 family (manual) with Local 3 for the following versions:

  • 1.30.04
  • 1.50.07
  • 1.50.08

Symptoms

 

The loading motor moves to a position different than the value entered in the Go Pos parameter.


Cause

 
  • Encoder Position Factor parameter
  • Pos Factor parameter

Solution

  The following changes improve loading motor reliability. They also greatly improve the registration test.
  • Change the Encoder Position Factor value from the default (4) to 1.
  • Change the Pos Factor value from the default (-0.0124788) to ‑0.00301139.

Note: Both parameters are found under HKEY_LOCAL_MACHINE\SOFTWARE\Scitex\Projects\LOTEM400V\IO OBJECTS\LOCAL 3\DC MOTORS\Plate Loading Motor\

 


See also

 

Release notes version 1.50.08 (page 7, para 11)


Technical contact(s)
 

Mario Amir

Submitted by
 

Mario Amir

Date submitted
 

10 Oct 2002