Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Error message "This program has performed an illegal operation" appears on Lotem 400


Product

 
  • Lotem® 400 platesetter
  • Lotem 400 Xpose
  • Lotem 200K

Error Message

 
  • This program has performed an illegal operation and will be shut down.
    If the problem persists contact the program vendor
    DETAILS:
    Program:C:\Lotem\Lotem400VGUI.exe
    File: wincore.ccp
    Line 980
  • Lotem400GUI caused a invalid page fault in Module PLATEEDGEDETECTION.DLL

Cause

 

In the registry, the Open parameter under IO OBJECTS > Plate Edge Detection System was changed from 1 to 0 in an attempt to deactivate edge detection.


Solution

 
  1. In the registry, browse to IO OBJECTS > Plate Edge Detection System, and change the Open parameter from 0 to 1.
  2. If you must deactivate the edge detection operation, in the registry, browse to Lotem400V > EXPOSE, and change the Plate Edge Detection Enable parameter from 1 to 0.

Technical contact(s)
 

Mario Amir

Submitted by
 

Ido Shatzky

Date submitted
 

12 Nov 2003


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.